About dyno controller modes, Access maintenance mode – Grass Valley K2 Dyno S v.3.0 User Manual
Page 36

Chapter 3 Service procedures
About Dyno Controller modes
K2 Dyno S Replay Controller
36
Installation & Service Manual
4 December 2012
3. Use the following table to isolate the problem.
About Dyno Controller modes
The Dyno Controller operates in the following modes:
• Dyno mode – The Dyno application is automatically launched at startup.
• Maintenance mode – The Dyno application is closed and the Windows operating
system desktop is available for system tasks such as network configuration, software
update, and determining Windows Operating System version.
By default, the K2 Dyno Replay Controller is in the Dyno mode. You must manually put
the unit in the maintenance mode, which requires a restart.
Access maintenance mode
1. Touch the
HOME
or
CONFIG
tab on the touchscreen to access one of these screens.
2. Press the Dyno Controller
SHIFT
button and then touch
Exit
on the touchscreen.
3. Touch the Shutdown Mode button to select
Maintenance
.
If the problem appears on these components…
It indicates the cause and corrective actions are as follows:
Dyno
Panel
Dyno Touch
Screen
Dyno Ext.
Display 1
Dyno Ext.
Display 2
Summit
Display
x
Faulty control panel. Replace control panel UI board.
x
x
Faulty software. Reimage Dyno.
x
x
x
Faulty software or motherboard. Reimage Dyno. If problem
remains, replace motherboard.
x
x
x
x
Faulty network connection or video/audio feed. Check
network and video/audio source.
x
Faulty software or LCD touch screen. Reimage Dyno. If
problem remains, replace LCD screen
x
x
Faulty software. Reimage Dyno.
x
x
x
Faulty video/audio feed. Check video/audio source.
x
Faulty computer display connection or monitor. Check
connections and monitor. If using a DVI or VGA monitor,
check DisplayPort adapter.
x
An active DisplayPort adapter is required when using two
External displays. Two passive adapters (like the one
provided) will not work. Use a passive and active DisplayPort
adapter, or two active DisplayPort adapters.
x
Summit problem. Check connections. Reimage Summit.