beautypg.com

Site requirements, Power requirements – Grass Valley Aurora Edit LD v.6.0a Installation User Manual

Page 28

background image

Chapter 2

Setting Up the Hardware

28

Aurora Edit Installation and Configuration Guide

Site Requirements

This section details site requirements for your Aurora Edit system.

Power Requirements

It is highly recommended that you use a surge protector and an uninterruptible
power supply (UPS) with your system. There must be a 20 A, 110 to 120 V
alternating current, 60 Hz or 10 A, 220 to 224 V alternating current, 50 Hz
circuit breaker and an isolated ground.

Storage upgrades may require additional electrical service. Consider the
equipment nameplate ratings and consult your Thomson Grass Valley
representative.

The Aurora Edit system is designed to work with a single-phase (three-wire)
power cord with a grounded neutral conductor. To reduce the risk of electric
shock, always plug the cord into a powered off grounded power outlet.

For best performance, keep all system power connections on the same power
feed distribution panel. Do not connect any other equipment to the same outlet
that is powering the Aurora Edit equipment.

This table lists the power requirements for the system components.

Component Voltage

Frequency

Power

Aurora Edit Workstation

120/240 VAC

50/60

700 Watts

17" Monitor
(optional; spec based on Viewsonic A70)

100/240 VAC

50/60

2 Amps

Mackie 1402VLZ Pro (optional)

120/240 VAC

50/60

25 W

Fostex Speakers (optional)

120 VAC

5 W

Brocade Silkworm 2400 (optional 8 port)

100/240 VAC

50/60

1.5 Amps

Brocade Silkworm 2800 (optional 16 port)

100/240 VAC

50/60

1.5 Amps

Netgear FS516 Ethernet Switch
(optional 16 port)

100/240 VAC

50/60

29 W

This manual is related to the following products: