beautypg.com

Replacing a power monitoring module – H3C Technologies H3C S12500 Series Switches User Manual

Page 89

background image

79

Replacing a PEM (applicable to only the S12504 AC power
supply)

Only the S12504-AC requires the PEM replacement.
To replace the PEM:

1.

Use a Phillips screwdriver to loosen the screws on the front panel of the PEM.

2.

Slowly pull the PEM out along the slide rails, as shown in

Figure 61

.

3.

Put the removed PEM on an antistatic mat or in its original shipping materials.

4.

Unpack a new PEM, and slowly insert the PEM along the slide rails until the PEM has close contact
with the power frame backplane, as shown in

Figure 61

.

5.

Use a Phillips screwdriver to fasten the screws on the PEM panel.

Figure 61 Replacing the PEM

A: PEM to be removed

B: PEM to be installed

Replacing a power monitoring module

To replace the power monitoring module:

1.

Remove the power monitoring module.

a.

Loosen the captive screws on the power monitoring module.

b.

Pull out the power monitoring module slowly along the slide rails.

3

4

1

2

B

A