beautypg.com

Managing the power supply system – H3C Technologies H3C S12500 Series Switches User Manual

Page 67

background image

57

Task Command

Remarks

In standalone mode, reboot a
card, or the switch
immediately.

reboot [ slot slot-number ] [ force ]

Available in user view.
If you reboot the active MPU or do not

specify the slot keyword, the reboot
command reboots the switch.

In IRF mode, reboot an IRF
member switch, a card on the

switch, or all IRF member
switches.

reboot [ chassis chassis-number
[ slot slot-number ] ] [ force ]

Available in user view.
If you reboot the active MPU or do not
specify the slot keyword, the reboot

command reboots the member switch.

To schedule a reboot:

Task Command

Remarks

Specify the reboot date and
time.

schedule reboot at time [ date ]

Available in user view.
By default, the scheduled reboot

function is disabled.
You can use either one of these
commands to schedule reboot time for a

standalone switch or all member

switches in IRF mode.
The reboot schedule becomes invalid in
the following cases:

An active and standby switchover

occurs in standalone mode.

An active and standby switchover

occurs on the master switch in IRF

mode.

Specify the reboot delay time. schedule reboot delay time

Managing the power supply system

You can use the following display commands and proper configuration commands to manage the power

supply system of your switch.

Displaying the electrical label data for the power monitoring
module

Use the display device manuinfo power-monitor command to display the electrical label data for the

specified power monitoring module.

In standalone mode:
# Display the electrical label information about power monitoring module 2.

display device manuinfo power-monitor 2

Power Monitor unit 2:

DEVICE_NAME : PMU

DEVICE_SERIAL_NUMBER : 210235A36L1234567890

MAC_ADDRESS : NONE