Disabling alarm traps for transceiver modules – H3C Technologies H3C S12500 Series Switches User Manual
Page 83

73
# Display the currently measured values of the fault detection parameters of the transceiver plugged in
interface GigabitEthernet 3/0/1.
GigabitEthernet3/0/1 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)
36 3.31 6.13 -35.64 -5.19
Table 21 Command output
Field Description
transceiver diagnostic information
Digital diagnosis information of the transceiver module on the
interface.
Temp.(°C)
Digital diagnosis parameter—Temperature, in °C, accurate to 1°C.
Voltage(V)
Digital diagnosis parameter—Voltage, in V, accurate to 0.01 V.
Bias(mA)
Digital diagnosis parameter—Bias current, in mA, accurate to 0.01
mA.
RX power(dBM)
Digital diagnosis parameter—RX power, in dBM, accurate to 0.01
dBM.
TX power(dBM)
Digital diagnosis parameter—TX power, in dBM, accurate to 0.01
dBM.
Disabling alarm traps for transceiver modules
If you install a transceiver module that has no vendor name or a vendor name other than H3C, the system
repeatedly outputs traps and logs to notify the user to replace the module. To continue to use such a
transceiver module that is manufactured or customized by H3C but has no vendor information, you can
disable alarm traps so the system stops outputting alarm traps.
Table 22 Disabling alarm reporting for the transceiver module
Step Command Remarks
1.
Enter system view.
system-view
N/A
2.
Disable alarm traps for
transceiver modules.
transceiver phony-alarm-disable
By default, alarm traps are
enabled for transceiver
modules.