Verification after power-on – H3C Technologies H3C S12500 Series Switches User Manual
Page 58

48
4.
Press Enter to begin configuring the switch at the prompt:
NOTE:
•
The S12500 routing switches provide a command line interface (CLI). For more information about
the CLI, see
H3C S12500 Routing Switch Series Fundamentals Configuration Guide.
•
The output depends on your switch model.
Verification after power-on
H3C recommends that you check the following conditions after the switch is powered on:
•
The cooling system is operating. You should be able to hear fan rotation noise and feel air being
blown out.
•
All the system LEDs on the MPUs are functioning correctly.
Table 11 LED status when the S12504 operates correctly
Module LED
Status
MPU
SFC (red and green)
Flashing green
LC (red and green)
Flashing green
FAN (red and green)
Flashing green
PWR (red and green)
Flashing green
ACT (green)
Steady on
RUN (red and green)
Flashing green
LPU
RUN (red and green)
Flashing green
Switching fabric module RUN (red and green)
Flashing green
Power monitoring
module
RUN (green)
Steady on
MAJOR (red)
Off
MINOR (yellow)
Off
Fan
RUN (green)
Flashing
ALM (red)
Off
Table 12 LED status when the S12508/S12518 operates correctly
Module LED
Status
MPU
SFC (red and green)
Flashing green
LC (red and green)
Flashing green
FAN (red and green)
Flashing green
PWR (red and green)
Flashing green
ACT (green)
Steady on
RUN (red and green)
Flashing green