Configuring temperature thresholds for a card – H3C Technologies H3C S12500 Series Switches User Manual
Page 72

62
----- ------- ---------- ---------------- ---------------- --------------
Info1 220 2000 CP2000AC54PE 1:18 12CS39016731
Info2 220 2000 CP2000AC54PE 1:18 12CS39016230
Configuring temperature thresholds for a card
You can set temperature thresholds for a card. When the temperature reaches a threshold, the switch
generates logs and alarm messages.
Configuring temperature thresholds for a card
Step Command
1.
Enter system view.
system-view
2.
Configure temperature
thresholds for a card.
•
In standalone mode:
temperature-limit slot slot-number { inflow | hotspot | outflow }
sensor-num lowerlimit warninglimit [ alarmlimit ]
•
In IRF mode:
temperature-limit chassis chassis-number slot slot-number { inflow |
hotspot | outflow } sensor-num lowerlimit warninglimit [ alarmlimit ]
Displaying the temperature information on your switch
Use the display environment command to display the temperature information of the sensors on the cards,
including the current temperature and temperature thresholds.
# Display the temperature information of the cards on the switch.
•
In standalone mode:
System temperature information (degree centigrade):
-------------------------------------------------------------------------------
Slot Sensor Temperature LowerLimit WarningLimit AlarmLimit ShutdownLimit
1 inflow 1 21 -25 70 80 N/A
1 outflow 1 24 -15 70 85 N/A
1 hotspot 1 27 -15 75 85 N/A
5 inflow 1 27 -20 65 85 N/A
5 outflow 1 27 0 70 85 N/A
5 hotspot 1 30 -10 70 80 N/A
12 inflow 1 23 -10 55 80 N/A
12 outflow 1 42 5 85 95 N/A
•
In IRF mode:
System temperature information (degree centigrade):
-------------------------------------------------------------------------------
Slot Sensor Temperature LowerLimit WarningLimit AlarmLimit ShutdownLimit
1/1 inflow 1 21 -25 70 80 N/A
1/1 outflow 1 24 -15 70 85 N/A
1/1 hotspot 1 27 -15 75 85 N/A