Maximum overrange multi-mode

-14 dBm

Minimum transmission length, including 3 dB
system reserve, when using single-mode

36 km glass fiber with F-G 9/125 0,36 dB/km

32 km glass fiber with F-G 9/125 0,4 dB/km
26 km glass fiber with F-G 9/125 0,5 dB/km
Maximum transmission power single-mode

-8 dBm

Minimum transmission power single-mode

-15 dBm

Minimum recierver sensitivity single-mode

-31 dBm

Maximum overrange single-mode

-7 dBm

Transmission speed

100 MBps

RS-232 (V.24) communication interface
Number

1

Connection format

Mini-DIN female connector on the switch

Floating alarm contact
Voltage

24 V DC

Current carriyng capacity

100 mA, maximum

Table A.2 – Interfaces

Mechanical Tests

Shock test according to IEC 60068-2-27

Operation: 25g, 11 ms period, half-sine shock
pulse Storage/transport: 50g, 11 ms period,
half-sine shock pulse

Vibration resistance according to IEC 60068-
2-6

Operation/storage/transport: 5g, 150 Hz,
criterion 3

Free fall according to IEC 60068-2-32

1 m

Table A.3 – Mechanical Tests

Conformance With EMC Directives

Developed according to IEC 61000-6.2
Noise emission according to EN55022: 1998 +
A1: 2000 + A2: 2003 (interference voltage)

Class A (industrial applications)

Noise emission according to EN55011: 1998 +
A1: 1999 + A2: 2002 (electromagnetic interfer-
ence)

Class A (industrial applications)

Noise immunity according to EN61000-4-2
(IEC1000-4-2) (ESD)
Contact discharge:
Air discharge:
Indirect discharge:

Requirements according to DIN EN 61000-6-2

Test intensity 2, criterion B