beautypg.com

Connecting the display station to the host system, Preliminary operating test – Visara 1481 User Manual

Page 18

background image

2-6

701408-002

Customer Installation

Connecting the Display Station to the Host System

Connect the display station to the host or to a controller with a coax cable up to 1500
meters (4920 feet) long, or a twisted-pair cable with a minimum length of 30.5 meters
(100 feet) and a maximum length of 277 meters (900 feet). Coax cable and twisted-pair
cables can be combined. This formula shows lengths:

(coax length) + (5 x twisted-pair length) < 1370 meters (4500 feet)

Follow these steps to connect the display station to the host system or to a controller:

1) Locate the coax or twisted-pair cable extending from the controller.

2) Align the end of the connector cable with the Dual Purpose connector on the back of

the Display/Logic element (see Figure 2-4). Connect the cable and secure it in place
by turning the retaining ring clockwise until it is tight.

Figure 2-4. 1481 Receptacle Connectors

Preliminary Operating Test

1) Ensure that the system control unit is powered on and operational.

2) Set the Power-On/Off switch to On ( | ) while simultaneously holding down any key

except the Reset key. After a few seconds, an alarm sounds.

3) Hold the key down until a screen resembling the one in Figure 2-5 appears. If the

screen remains blank, the Contrast and Brightness controls may need adjusting.