beautypg.com

Cables and connectors, 1 sdb, 1 sdb connector – Sundance SMT310Q User Manual

Page 38: 2 comports, 1 fms cabling, Fms cabling, Cables and connectors 12.1

background image

Version 2.1

Page 38 of 55

SMT310Q User Manual

12. Cables and Connectors

12.1

SDB

No SDB cables are supplied with the SMT310Q. You can order them separately
from Sundance with part number SMT510-SDBxx, where xx is the cable length
in centimetres.

12.1.1 SDB Connector

Function Pin

Pin Function

Function

Pin

Pin Function

GND 2

1 CLK

D9

21 22 GND

GND 4

3 D0

D10 23 24 GND

GND 6

5 D1

D11 25 26 GND

GND 8

7 D2

D12 27 28 GND

GND 10

9 D3

D13

29 30 GND

GND 12

11 D4

D14

31 32 GND

GND 14

13 D5

D15

33 34 GND

GND 16

15 D

6 USERDEF0 35 36 GND

GND 18

17 D7

WEN 37 38 REQ

GND 20

19 D8 USERDEF1 39 40 ACK

Table 12: SDB Pin-out

12.2

Comports

12.2.1 FMS Cabling
The cables used with FMS connectors are not supplied with the SMT310Q.
You can order them separately from Sundance with part number SMT500-
FMSxx, where xx is the cable length in centimetres.
When fitting FMS cables, make sure they have a twist: one end must have the
blue side facing out and the other must have the silver side facing out.

Important Note.

If using FMS cables between two SMT310Qs

4

the reset headers must be

connected to ensure that all comports reset at the same time.

See Reset and Config headers

4

This is not recommended as long FMS cables can introduce communication problems.