beautypg.com

Delta Electronics AC Drive VFD-F Series User Manual

Page 26

background image

English-26

Parameter

Functions

Settings

Factory

Setting

Customer

11-06 Motor

Switch

Frequency

during Fixed Amount
Circulation

0.00 to 120.00 Hz

60.00

11-07

Enter Sleep Process
Time

0.0~3600.0sec
0.0: Sleep function disable

0.0

11-08

Sleep Frequency of
Sleep Process

0.00 to 11-09 (Wake up Frequency)

0.0

11-09

Wake Up Frequency of
Sleep Process

0.00 to 120.0Hz

0.0

11-10

Treatment of Fixed
Amount Circulation
Malfunction

00: Turn off all motors
01: Turn off AC drive

00

11-11

Stop Frequency of
Auxiliary Motor

0.00~120.00Hz 0.00


Fault Codes

Fault

Name

Fault Descriptions

Corrective Actions

Software
protection failure

Return to the factory.

GFF hardware
error

Return to the factory.

CC (Current
Clamp)

Return to the factory.

OC hardware error

Return to the factory.

OV hardware error

Return to the factory.

OH hardware error

Return to the factory.

Over current
Abnormal increase
in current.

1. Check whether the motors horsepower corresponds to the

AC drive output power.

2. Check the wiring connections between the AC drive and

motor for possible short circuits.

3. Increase the Acceleration time.
4. Check for possible excessive loading conditions at the motor.
5. If there are any abnormal conditions when operating the AC

drive after short-circuit being removed, it should be sent back
to manufacturer.

Over voltage
The DC bus voltage
has exceeded its
maximum allowable
value.

1. Check whether the input voltage falls within the rated AC

drive input voltage.

2. Check for possible voltage transients.
3. Bus over-voltage may also be caused by motor regeneration.

Either increase the decel time or add an optional brake
resistor.

4. Check whether the required brake power is within the

specified limits.