Group 4 Input Function Parameters
Parameter
Functions
Settings
Factory
Setting
Customer
04-00 Multi-function
Input
terminal 1
01
04-01 Multi-function
Input
terminal 2
02
04-02 Multi-function
Input
terminal 3
03
04-03 Multi-function
Input
terminal 4
04
04-04 Multi-function
Input
terminal 5
05
04-05 Multi-function
Input
terminal 6
07
04-06 Multi-function
Input
terminal 7
08
04-07 Multi-function
Input
terminal 8
00: No function
01: Multi-Speed terminal 1
02: Multi-Speed terminal 2
03: Multi-Speed terminal 3
04: Multi-Speed terminal 4
05: Reset (NO)
06: Reset (NC)
07: Jog operation (JOG)
08: Accel/Decel disable
09: Accel/Decel 2 selection
10: Accel/Decel 3 selection
11: B.B. (NO) input
12: B.B. (NC) input
13: Increase Frequency
14: Decrease Frequency
15: Emergency stop (NO)
16: Emergency stop (NC)
17: AVI (open), ACI1 (close)
18: KEYPAD (open), EXT (close)
19: PID disable
20: Auxiliary 1 input
21: Auxiliary 2 input
22: Auxiliary 3 input
23: Auxiliary 4 input
24: Auxiliary 5 input
25: Auxiliary 6 input
26: Auxiliary 7 input
27: Motor No.1 output disable
28: Motor No.2 output disable
29: Motor No.3 output disable
30: Motor No.4 output disable
31: All motor output disable
32: Run PLC Program
33: Pause PLC Program
09
04-08 Digital
Input
Terminal
Response Time
01~20 01
04-09
AVI Minimum voltage
0.0~10.0V
0.0
04-10 AVI
Maximum
voltage 0.0~10.0V
10.0
04-11 AVI
Minimum
frequency
(percentage of Pr.1-00)
0.00~100.00% 0.00
04-12
AVI Maximum frequency
(percentage of Pr.1-00)
0.00~100.00% 100.00
04-13
ACI1 Minimum current
0.0~20.0mA
4.0
04-14
ACI1 Maximum current
0.0~20.0mA
20.0
04-15 ACI1
Minimum
frequency (percentage
of Pr.1-00)
0.0~100.0% 0.00
04-16 ACI1
Maximum
frequency (percentage
of Pr.1-00)
0.0~100.0% 100.00
04-17
ACI2 Minimum current
0.0~20.0mA
4.0
04-18
ACI2 Maximum current
0.0~20.0mA
20.0