Delta Electronics AC Drive VFD-F Series User Manual
Page 14
English-14
Parameter
Functions
Settings
Factory
Setting
Customer
Bit 9: Master frequency source via analog
Bit10: Running command via communication
interface
Bit11: Parameter locked
Bit12~15: Reserved
00-03
Frequency Setting
Read only
Read
00-04
Output Frequency
Read only
Read
00-05
Output Current
Read only
Read
00-06
DC-BUS Voltage
Read only
Read
00-07 Output
Voltage
Read
only
Read
00-08
Output Power Factor Read only
Read
00-09
Output Power (kW)
Read only
Read
00-10 Feedback
Signal
Actual Value
Read only
Read
00-11
Feedback Signal (%) Read only
Read
00-12
User Target Value
(Low bit) uL 0-99.99
Read only
Read
00-13
User Target Value
(High bit) uH 0-9999
Read only
Read
00-14
PLC time
Read only
Read
Group 1 Basic Parameter (Twice the value for 460V class)
Parameter
Functions
Settings
Factory
Setting
Customer
01-00 Maximum
Output
Frequency
50.00~120.00Hz 60.00
01-01 Maximum
Voltage
Frequency (Base
Frequency)
0.10~120.00 Hz
60.00
01-02 Maximum
Output
Voltage
230V series: 0.1~255.0V
460V series: 0.2~510.0V
220.0
440.0
01-03
Mid-point Frequency
0.10~120 Hz
1.50
01-04
Mid-point Voltage
230V series: 0.1~255.0V
460V series: 0.2~510.0V
5.5
11.0
01-05 Minimum
Output
Frequency
0.10~20.00 Hz
1.50
01-06
Minimum Output Voltage 230V series: 0.1~50.0V
460V series: 0.2V~100.0V
5.5
11.0
01-07
Upper Bound Frequency 0.00~120.00 Hz
60.00
01-08
Lower Bound Frequency 0.00~120.00 Hz
0.00
a01-09 Acceleration Time 1
0.1~3600.0 Sec
10.0/
60.0
a01-10 Deceleration Time 1
0.1~3600.0 Sec
10.0/
60.0
a01-11 Acceleration Time 2
0.1~3600.0 Sec
10.0/
60.0
a01-12 Deceleration Time 2
0.1~3600.0 Sec
10.0/
60.0
a01-13 Acceleration Time 3
0.1~3600.0 Sec
10.0/
60.0