For The Installer: Remote Condenser

Locate the condenser as near as possible to the

interior location of the ice machine.
Note: The location of the condenser is relative to

the ice machine is LIMITED by the specification on

the prior page.

Meet all applicable building codes.
Roof Attachment
Install and attach the remote condenser to the roof

of the building, using the methods and practices of

construction that conform to the local building

codes, including having a roofing contractor secure

the condenser to the roof.
Precharged Line Routing
Do not connect the precharged tubing

until all routing and forming of the

tubing is complete. See the Coupling

Instructions for final connections.
1. Each set of pre-charged tubing lines

contains a

3

8

” diameter liquid line,

and a

1

2

” diameter discharge line. Both

ends of each line have quick connect

couplings, the end without access

valves goes to the ice maker.
Note: The openings in the building

ceiling or wall, listed in the next step,

are the minimum sizes recommended

for passing the refrigerant lines

through.
2. Have the roofing contractor cut a

minimum hole for the refrigerant lines

of 1

3

4

”. Check local codes, a separate

hole may be required for the electrical

power supply to the condenser.
Caution: Do NOT kink the refrigerant

tubing while routing it.
3. Route the refrigerant tubes thru the

roof opening. Follow straight line

routing whenever possible. Excess

tubing may EITHER be coiled up

INSIDE the building OR cut out prior to

connection to the ice maker and

condenser.
If the excess tubing is cut out, after

re-brazing the tubing must be

evacuated prior to connection to the

ice maker or condenser.

If the excess tubing is to be coiled, spiral it

horizontally to avoid excess trapping in the lines.
5. Have the roofing contractor seal the holes in the

roof per local codes.

CME506R, 656R, 806R: AutoIQ Cubers

January 2000

Page 7

Condenser Line Set

Connections

Coil Excess Line Set

Horizontally Inside the

Building

Ice Machine

Refrigeration Line

Set Connections