Removal and Replacement

Inlet Water Valve

1. Remove the front panel.
2. Shut off the water supply.
3. Push and release the OFF button.
4. Pull the wire harness off the inlet water valve.
5. Remove screws holding the inlet water valve to

the cabinet.
6. Pull the valve away from the cabinet and

disconnect the outlet tube.

7. Unscrew the water valve from the water inlet

tubing. Hold the barbed inlet fitting and rotate the

valve.
8. Reverse to reassemble.
9. Push and release the Freeze button.
10. Replace the front panel.

Water Pump
1. Disconnect the electrical power.
2. Remove the front panel.
3. Unplug water pump from its electrical

connection.
4. Remove 1 plastic bolt and the reservoir cover.
5. Lift water pump up and disconnect outlet tube.
6. Pull float ball from float stem (it is a snap fit).

Pull stem out.
7. Locate water level sensor mounting tabs,

compress together to release sensor from bracket.
8. Remove water pump brackets from pump.
9. Reverse to replace.
10. Replace front panel.
11. Re-connect electrical power.