Technicians Only: Harvest Cycle Operational Sequence

Harvest

The water valve opens and fills the reservoir to the

Full level.
The water pump shuts off. It will restart in less than

a minute.
Note: Machines built after August 1996:

If the machine remains in the harvest cycle

for longer than between 6 -9 minutes

(depending upon the regular harvest cycle’s

length) the water pump will be switched off

until the next freeze cycle.

When the bin is full and the unit is in a

harvest cycle, the pump will be switched off.

The AutoIQ Controller checks how long it takes to

fill the reservoir, and if it was too much time, the

machine Shuts Down on Water Error.
Note: The machine will automatically attempt to

restart after shutting down because of a lack of

water. The time between restarts is about 30

minutes.
The inlet water valve will stay on and open for a

predetermined fraction of the time it took to fill the

reservoir. This overflows and rinses the reservoir

water.
During the Harvest Cycle, ice will be falling from

the evaporators and between the bin control’s

electric eyes. The AutoIQ Controller monitors the

ice falling and stays in the Harvest Cycle until ice

quits going thru the electric eyes.
The maximum harvest time is 10 minutes. Harvest

time is varied by the AutoIQ Controller based the

time it took the last batch of ice to fall.
The first Harvest after a restart will take about 5

minutes to establish a base line, then the time it

took to release that ice is used to determine the

next harvest cycle’s length.
If no cubes fall (or are sensed) by the end of the

Maximum Harvest Time, the machine senses a

Refrigeration Error. If the next cycle also produces

a Refrigeration Error, the machine will shut down.
Note: Machines built up to August 1996: The last

Harvest cycle before shutting off on Bin Full will be

10 minutes. All CME806 and all other machines

built after August 1996 have a last harvest

cycle that is 4-6 minutes long.

Note: The machine will not restart for 4 minutes

after switching off on Bin Full, unless the Freeze

button is pressed.
Stacked Units:
If the bottom unit is in harvest and receives a

signal from the top unit that it is also in Harvest,

the bottom unit will stay in harvest for its Maximum

Harvest Time.
Diagnostic Lights and Manual Resets
The controller will shut the machine off if a

malfunction is sensed. Controllers up to 17-1 will

shut the machine off after the first malfunction.

Controllers marked 17-1 and up will restart the

machine 2 times, with a 50 minute interval

between restarts.
If a malfunction is still present after the second

restart, the machine will then shut off and must be

manually reset. During the restart interval, the

machine will be off and a diagnostic code

indicated.
An exception to this is lack of water. When

switched off because of lack of water, the machine

will always try to re-fill the reservoir every 20

minutes.
Another exception is a harvest error. As before,

there must be two consecutive harvest errors to

trigger a machine shut-down. With this change, the

controller will still shut down and restart the

machine after two consecutive harvest errors.

However, if the errors repeat two more

consecutive times, the controller will shut down

and restart the machine again. If the machine

registers two more consecutive harvest errors, the

machine will again shut down and must be

manually reset.
Production of units with Controllers 17-1 began

approximately March 1997.