beautypg.com

Operational characteristics: cme806r – Scotsman CME506R AutoIQ User Manual

Page 34

background image

CME506R, 656R, 806R: AutoIQ Cubers

January 2000

Page 34

Operational Characteristics: CME806R

Cycle Times (minutes):

System Pressures (PSIG):

Refrigerant Charge

CME806R uses 232 ounces when connected to ERC201, or 280 ounces when connected to

ERC402. All R-404A.

Typical Compressor Amp, single phase

Freeze - 13

Harvest - 14

Typical Harvest Ice Weight

6.5 - 7 lb.

70

o

F. condenser air 70

o

F. indoor

air, 50

o

F. water

90

o

F. condenser air 90

o

F. indoor

air, 70

o

F. water

Freeze

10 - 12

11:30 - 13

Harvest

1:45

1:30

70

o

F. condenser air 70

o

F. indoor

air, 50

o

F. water

90

o

F. condenser air 90

o

F. indoor

air, 70

o

F. water

Suction: End of Freeze

19 - 21

21 - 23

Suction: Peak in Harvest

100 - 110

115 - 125

Discharge: 5 minutes into Freeze

225

245

Discharge: Minimum in Harvest

180

190

This manual is related to the following products: