Adjustments:

If there was a problem during Initial Start

Up:

If an error light came on, check the following.
1. Water error.
A water error could have been determined by the

AutoIQ Controller if the inlet water valve does not

fill the reservoir or if the water pump does not start

and lower the water level in the reservoir. If either

condition is found, the water error light will be

switched on and the machine will Shut Down.
2. Refrigeration error.
A refrigeration error could have been determined

by the AutoIQ Controller if the water temperature

did not drop during the freeze cycle. The

Controller will next check the compressor

discharge temperature. If the discharge

temperature is too low, the refrigerant error light

will be switched on, and the machine will Shut

Down.

Note: The machine can be reset and restarted by

pushing and releasing the Off push button switch,

and then pushing and releasing the freeze push

button switch.

How to Adjust Cube Size (Reference Only)

The adjustment is done by moving the long screw

located in the floating stem at the front of the

machine.
Note: Units manufactured beginning 3/97 do not

have a cube size adjustment screw. Their cube

size is fixed.

1. Remove the front panel.
2. Hold the stem with one hand, and
To increase the cube size, turn the screw out

(counter clockwise)
To decrease the cube size, turn the screw in

(clockwise)
Turn the screw 2 turns at a time.
3. Check cube size after the next freeze cycle,

repeat step 2 if needed.

CME506R, 656R, 806R: AutoIQ Cubers

January 2000

Page 16

Side View, Cube

should be 1/2" thick

at the center.

Front View,

cube is 1.5" x 1.4"

Cube Size

Adjustment

Screw

Adjust Cube Size