beautypg.com

Additional maintenance: bin controls, condenser – Scotsman CME506R AutoIQ User Manual

Page 26

background image

Additional Maintenance: Bin Controls, Condenser

The bin controls use a system of infrared emitting

and receiving components to sense the build up of

ice in the bin. They are located at the bottom of the

ice outlet port. They must be free of mineral build

up to function properly. To check:
1. Remove front panel.
2. Push and release the off button.
3. Remove top and right side panels.
4. Remove the evaporator cover.
5. Remove the cube deflector.
6. Push into the freezing compartment the electric

eye brackets.

7. Examine the bottom of the brackets, there are

two sensors in each bracket, check that they are

clear of mineral build up. They may be wiped clean

with ice machine cleaner to assist in removal of the

build up.
Note: Do NOT use abrasive materials or cleaner

on the bin sensor lenses.

To Clean the Remote Air Cooled

Condenser

1. Disconnect and lock out the electrical power.
2. At the remote condenser, check for loose debris

on the roof, remove any near the condenser.
3. Check the fan blade and condenser for grease

or dust build up. Brush the surface (bottom) of the

condenser with a nylon brush to remove surface

dirt. Use a fin comb to straighten any bent fins.
Note: Air flow is UP, towards the fan.
If grease is present, use coil cleaner on the

condenser. Be sure to wipe up any excess coil

cleaner.

4. Reconnect the electrical power.

CME506R, 656R, 806R: AutoIQ Cubers

January 2000

Page 26

Bin Control Sensor,

Electric Eye Area

Bin

Controls in

Reservoir

This manual is related to the following products: