Operational Characteristics: CME656R

Cycle Times (minutes):

System Pressures (PSIG):

Refrigerant Charge

CME656R uses 232 ounces when

connected to ERC201, or 280 ounces when

connected to ERC402. All R-404A.

Typical Compressor Amp, single phase

9 - 13 freeze

13 - 18 harvest

Typical Compressor Amps, three phase

6 - 7 freeze

9 - 10 harvest

Typical Harvest Ice Weight

6.5 - 7 lb.

CME506R, 656R, 806R: AutoIQ Cubers

January 2000

Page 33

0

o

F. condenser air 70

o

F. indoor air,

55

o

F. water

90

o

F. condenser air 90

o

F. indoor

air, 70

o

F. water

Freeze

13 - 15

15 - 17

Harvest

3

1:30

0

o

F. condenser air 70

o

F. indoor air,

55

o

F. water

90

o

F. condenser air 90

o

F. indoor

air, 70

o

F. water

Suction: End of Freeze

24 - 27

27 - 29

Suction: Peak in Harvest

85 - 105

100 - 110

Discharge: 5 minutes into Freeze

240 - 260

265 - 295

Discharge: Minimum in Harvest

190 - 210

225 - 230