beautypg.com

Removal and replacement – Scotsman CME506R AutoIQ User Manual

Page 36

background image

Removal and Replacement

Drain Tubing
1. Remove the front panel.
2. Push and release the Off button.
3. Remove bin baffle.
4. Remove 1 plastic bolt and the reservoir cover.
5. Unplug water pump, disconnect ground wire.
6. Unplug water level sensor.

7. Lift pump up slightly and pull discharge hose

from pump.
8. Remove pump and water level sensor from

ice machine.
9. Pull up and forward to remove standpipe.
10. Disconnect back of cabinet drain system.
11. Remove nut on inside of reservoir (where

standpipe was).
12. From inside the bin, pull drain tube out of

the reservoir and down. Remove from machine.
13. Reverse to reassemble.

CME506R, 656R, 806R: AutoIQ Cubers

January 2000

Page 36

Water Sensor

Standpipe

Note: Standpipe height is critical.

Measured from the top of the

standpipe to the top of the reservoir,

the distance should be 2

5

8

". If not,

adjust it by rotating the top of the

standpipe (it is on threads) to obtain

that distance.

Water Level Sensor/Float Stem
1. Disconnect the electrical power.
2. Remove the front panel.
3. Remove 1 plastic bolt and the reservoir cover.
4. Pull float ball from float stem (it is a snap fit). Pull

stem out.
5. Locate water level sensor mounting tabs,

compress together to release sensor from bracket.
6. Remove harness from sensor.
7. Reverse to replace.
Note: Float stem slot opening is 2".
8. Replace front panel.
9. Re-connect electrical power.

This manual is related to the following products: