beautypg.com

Scotsman CME506R AutoIQ User Manual

Page 27

background image

Service Diagnosis: Controller Diagnostic Light Analysis

CME506R, 656R, 806R: AutoIQ Cubers

January 2000

Page 27

Problem or Symptom Possible Cause

Probable Correction

Machine is off

Bin is full, ice in cube port

Use some ice

Power is off, check lights.

If all lights are out, check power supply,

restore power if off

Transformer is open

If all lights are out and there is power, check

transformer output for 24 vac

Unit has been switched off

or has finished a Clean

cycle, Off light is glowing

Push and release Freeze button

Unit has Shut Down

Check for Refrigeration or Water Error

Unit is off & Water

Diagnostic Light is ON

or BLINKING

Water inlet valve

malfunction

Check water light, if the light blinks 2 times

and repeats, check the water inlet valve for

proper water flow.**

Water pump malfunction

Check that pump hose is attached and if

pump is plugged in and working.

Water level sensor may

have failed.

Check float stem, reset machine. If it will not

reset or gives another water error and all else

is OK, replace the water level sensor.

Unit is off and

Refrigeration

Diagnostic Light is ON

or BLINKING

Low discharge or long

freeze cycle

If the refrigeration lite is glowing continuously

there is a probable refrigeration problem

Harvest problem

Check refrigeration light. If thelight is blinking

steadily, look for a harvest problem.**On

controllers 17-1 and higher, this also indicates

that cubes were sensed by the bin controls.
Controllers 17-1 and higher, if the lite blinks 2

times and repeats, check for a harvest error -

no cubes sensed.

High Discharge Temp

Check refrigeration light. If the light blinks 3

times and then repeats, check for a reason for

high discharge temperatures - fan motor hot

ambient.

Unit does not go into

harvest - exceeds

maximum freeze time

Push and release Off button. Push and

release Freeze button. Check operation.
Push cube size float down, check operation.

Exceeds maximum harvest

time

Check for cause of long harvest cycle**

Unit runs and both

Error Lights are ON

Temperature sensors out

of range

Replace the temperature sensor set (water

and discharge).

Same, only 1 light on

Reservoir temp. wrong

Check water temp. and sensor.

* Machine may be reset by pushing and releasing the Off button, then pushing and releasing the

Freeze button. ** See following pages

This manual is related to the following products: