Telemetry Control

Flip

Users can track an object continuously when it passes through under the dome
camera with setting Flip to IMAGE (digital flip) or ME (mechanical flip).

IMAGE – Digital Image Flip, which enables users to keep tracking objects
seamlessly. Almost no delay occurs when compared to ME mode.

Note

The Privacy Mask function will be automatically disabled if the Image Flip
function is enabled, and the screen will display “MASK WILL BE SET OFF.”

ME (Mechanical Flip) – ME is a standard mechanical operation. As the
dome tilts to the maximum angle, it will pan 180°, and then continue tilting to
keep tracking objects.

Note

This function can only be controlled manually. If a Preset or a point for
another function is set in a position that can only be reached through a flip
motion, the position will not be reached if FLIP is turned off.

Off – Select this to disable the flip function.

Note

To make the dome tilt within a specific range, such as -10° to +100°, go to
ANGLE ADJUSTER (see next section) to set the angle range. Otherwise,
the default setting is 90°.

Angle Adjusters

Use Angle Adjuster to adjust the angle of view. The range of the view angle is
between -10° and +100° in the ME, FLIP and FLIP OFF modes, and between -10°
and +190° in the IMAGE FLIP mode.

TELEMETRY CTRL

FLIP

ENTER

ANGLE ADJUSTER

ENTER

PT POSITION

ENTER

SPEED BY ZOOM

OFF

AUTO CALIBRATE

OFF

PASSWORD

OFF

OSD AUTO CLOSE

20 SEC

SYSTEM RESET

ENTER

EXIT

YES