Niveo Professional NGSME16T2H User Manual
Page 290
Chapter 5: Monitor, Diagnostic, Maintenance
Monitor, Diagnostic, Maintenance
NGSME16T2H User Manual | 290
packets sent from the switch
towards the backend server for a
given port (left-most table) or client
(right-most table). Possible
retransmissions are not counted.
Last Supplicant/Client Info
Information about the last supplicant/client that attempted to authenticate. This
information is available for the following administrative states:
Port-based 802.1X
Single 802.1X
Multi 802.1X
MAC-based Auth.
Last Supplicant/Client Info
Name
IEEE Name
Description
MAC
Address
dot1xAuthLastEapolFrameSource The MAC address of the last supplicant/client.
VLAN ID
-
The VLAN ID on which the last frame from the last
supplicant/client was received.
Version
dot1xAuthLastEapolFrameVersion
802.1X-based:
The protocol version number carried in the most
recently received EAPOL frame.
MAC-based:
Not applicable.
Identity
-
802.1X-based:
The user name (supplicant identity) carried in the
most recently received Response Identity EAPOL
frame.
MAC-based:
Not applicable.