beautypg.com

Niveo Professional NGSME16T2H User Manual

Page 235

background image

Chapter 4: Feature Configuration - CLI
Featuring Configuration

– CLI

NGSME16T2H User Manual | 235

MSTI6 No VLANs mapped

MSTI7 No VLANs mapped

Port Setting

STP Port Mode

Syntax:

STP Port Mode [] [enable|disable]

STP Port Edge [] [enable|disable]

STP Port AutoEdge [] [enable|disable]

STP Port P2P [] [enable|disable|auto]

STP Port RestrictedRole [] [enable|disable]

STP Port RestrictedTcn [] [enable|disable]

STP Port bpduGuard [] [enable|disable]

STP Port Statistics [] [clear]

Example:

STP>port mode 1-24 dis (Disable STP on port 1-24)

STP>port edge 1-24 en (Enable Edge port on port 1-24)

STP>port autoedge 1-24 en (Enable Auto Edge on P1-24)

STP>port p2p 1-24 en (Enable P2P mode on P1-24)

STP>port p2p 1-24 auto (Enable Automatic P2P detection)

STP>port bpdu 1-24 en (Enable BPDUGuard on P1-24)

Port Path Cost

Syntax:

STP Msti Port Cost [] [] []

Parameters:

: STP bridge instance no (0-7, CIST=0, MSTI1=1, ...)

: Port list or 'all'. Port zero means aggregations.

: STP port path cost (1-200000000) or 'auto'

Example: Configure CIST 0 Port Path Cost