MDE-4298D CFN Series Site Controller III Installation Manual · September 2009
Page 47
Tokheim Pump PC Interface
Pump/Remote Dispenser Wiring
Tokheim Pump PC Interface
to establish an interface between the SCIII and Tokheim pumps/
dispensers.
Use the C05578 CFN to Tokheim 67/98 D-Box Cable Assembly and see
the selected PC COMM port of the SC III to a single Tokheim 67 or 98 Interface Box. If there
are more than 16 dispensers connected through two Tokheim 67 boxes, another COMM port
on the PC must be used and the wiring connections must be duplicated as shown in
Figure 5-3: Tokheim Pumps Electronic Interface: One Tokheim 67 or 98 Interface Box
PC COMM Port
(9-pin)
Power Supply
Signal Converter
(C05851)
M07493A001
Cable
Barrel Connector
Tokheim 67 or 98 Interface Box
CFN3
Use the C05577 CFN to Tokheim 98 D-Box Cable Assembly and see
the selected PC COMM port of the SC III to two Tokheim 98 Interface Boxes.
Figure 5-4: Tokheim Pumps Electronic Interface: Two Tokheim 98 Interface Boxes
PC COMM Port
(9-pin)
Signal Converter (C05851)
Power Supply
M07493A001
Cable
Barrel Connector
Tokheim 98 Interface Box
Tokheim 98 Interface Box
CFN3
If there are more than two Tokheim 98 Interface Boxes, the site will be required to use another
COMM port on the SC III PC and the connections must be duplicated as shown in
depending on whether there are three or four Tokheim 98 Interface Boxes.
Refer to the manufacturer’s instructions to connect Tokheim 67 or 98 Interface Boxes to the
Tokheim pumps/dispensers.