background image

Pump/Remote Dispenser Wiring

Gilbarco Pump PC Interface

Page 46 MDE-4298D CFN Series Site Controller III Installation Manual · September 2009

Gilbarco Pump PC Interface

See

Figure 5-1

to establish an interface between the SC III and Gilbarco pumps/dispensers.

Figure 5-1: Gilbarco Pumps/Dispensers Electronic Interface

C05981
Adapter

485

Input

DB9

IC-485S

Power

Supply

RJ11

Conn.

C05999

Cable

TB

CFN

3

C06253

DB9/DB25

C08087

IC-485S

Gilbarco

Distribution Box

set up for

RS-422

operation

This section connected according to
Gilbarco’s wiring instructions by a qualified
Gilbarco installer.

CURRENT LOOP

Pump

Pump

Pump

Com

Port

Note: Refer to MDE-4634 CFN Series Gilbarco Pump PC Interface for information on

connecting the Atlas 8800 to a CFN SC III.

Wayne Pump PC Interface

See

Figure 5-2

to establish an interface between the SC III and Wayne pumps.

Use a PC DB9 to DB25 Cable (Gasboy Part Number C05907) to connect the selected PC
comm port of the SC III to the male DB25 Connector of the Wayne Electronics Central
Cabinet.

Figure 5-2: Wayne Pumps Electronic Interface

CENTRAL CABINET

WAYNE ELECTRONICS

CFN3

DB9/DB25 CABLE

OR

DB25/DB25 CABLE

C05907

CFN 3 PC

UNUSED COM PORT

WAYNE PUMP CONTROL

INPUT CONNECTOR

WIRING TO WAYNE PUMPS WITH
CATS ACCORDING TO WAYNE’S
INSTALLATION MANUAL

Note: Use DB9-DB25 Cable if needed. Else, remove the DB9-DB25 Cable and use the

DB25-DB25 Cable.