beautypg.com

Addendum, General, Table 7.1 additional troubleshooting help – Comtech EF Data XPA-200 User Manual

Page 79

background image

XPA200-7984-I-OPT1, X-Band SSPA

Addendum

XPA200-7984-I-0PT1, Rev.2

7.1

Addendum

7.1 General

This addendum section contains additional items as listed

below:

1. Additional Troubleshooting helps (Table 7.1)

2. Wiring diagram.

3. Top level parts list.

7.2 Additional Troubleshooting Information.

Table 7.1

Additional Troubleshooting Help

SYMPTOM

POSSIBLE CAUSES

SOLUTIONS

Unit does not turn on

(no display, no front

panel lights, no

fans).

Power cord not plugged in.

Faulty wiring to 28V power

supply.

28V power supply fault.

Check power cord connections.

With input power cord

removed, check wiring and

connections to 28V power

supply.

Check output of 28Vdc power

supply.

Either one or both

fans do no turn on.

Faulty wiring, bad

Note: At power-up, the fans

are sequenced on. Therefore,

in normal operation, the

second fan does not turn on

until approximately 3 seconds

after the first fan.

Check AS/0206 to ensure that