beautypg.com

Command/response pairs – Comtech EF Data XPA-200 User Manual

Page 60

background image

XPA200-7984-I-OPT1, X-Band SSPA

Remote Control

Remote Control

XPA200-7984-I-OPT1, Rev.2

5-8

5.8 COMMAND/RESPONSE PAIRS

5.8.1 Utility Commands

5.8.1.1 Time

Set Time:

_hh:mm:ss'cr'

hh = Hour*

Confirmation:

>DEV/TIM_hh:mm:ss'cr''lf']

mm = Minutes

ss = Seconds

Retrieve Time: _'cr'
Confirmation:

>DEV/TIM_hh:mm:ss'cr''lf']

* Note: 24 hour military time is used.

5.8.1.2 Date

Set Date:

mm = Month

Confirmation:

>DEV/DAT_mm/dd/yy'cr'lf']

dd = Day

yy = Year

Retrieve Date: _'cr'

Confirmation:

>DEV/DAT_mm/dd/yy'cr''lf']

5.8.1.3 Physical Address

The default Physical Address from is 1.

Set Physical Address:

xxx = 1 to 255

Confirmation:

>DEV/SPA_xxx'cr''lf']

Retrieve Phys. Addr:

Confirmation:

>DEV/SPA_xxx'cr''lf']

5.8.1.4 Baud Rate

The default baud rate is 9600.

Set Baud Rate:

xxxx = 300,

Confirmation:

>DEV/SBR_xxxx'cr''lf'] 1200, 2400,

4800 or 9600

Retrieve Baud Rate: _xxxx'cr'

Confirmation:

>DEV/SBR_xxxx'cr''lf']