XPA200-7984-I-OPT1, X-Band SSPA

Remote Control

XPA200-7984-I-OPT1, Rev.2

5-4

5.3.3.2 RS-485

RS-485 cabling can be implemented with a single ribbon cable

using ‘IDC Mass Terminated’ style connectors or with discrete

wires using ‘solder-cup’ style connectors. A sufficient length

of ribbon cable must be allowed to reach the system monitor and

control computer.

5.4 PROTOCOL

5.4.1 Transmission Mode

The transmission mode is half duplex implemented in

Command/Response convention. This method requires the external

system monitor and control unit to initiate all communications by

command and the SSPA to respond with either confirmation or an

error message. The confirmation may contain status information.

5.4.2 Baud Rate

The default serial port Baud Rate is 9600. Baud rates of

4800, 2400, and 1200 and 300 are also supported.

5.4.3 Format

The following parameters are the default character format.

1 Start Bit

7 Data Bits

2 Stop Bits

1 Parity Bit

An optional character format that can be selected is:

This can only be selected from the Front Panel Menu.

1 Start Bit

8 Data Bits

1 Stop Bit

0 Parity Bits

5.4.4 Character Set

The character set implemented is ASCII.