XPA200-7984-I-OPT1, X-Band SSPA
Remote Control
Remote Control
XPA200-7984-I-OPT1, Rev.2
5-13
5.8.3.3 FET Status
FET Status:
Confirmation: >DEV/RFS_'cr' FET1_xxx'cr' FET1 current in milliamps FET2_x.x'cr' FET2 current in amps FET3_x.x'cr' FET3 current in amps FET4_x.x'cr' FET4 current in amps FET5_x.x'cr' FET5 current in amps FET6_x.x'cr' FET6 current in amps FET7_x.x'cr' FET7 current in amps FET8_x.x'cr' FET8 current in amps FET9_x.x'cr' FET9 current in amps FET10_x.x'cr' FET10 current in amps FET11_x.x'cr' FET11 current in amps FET12_x.x'cr' FET12 current in amps FET13_x.x'cr' FET13 current in amps FET14_x.x'cr' FET14 current in amps FET15_x.x'cr' FET15 current in amps FET16_x.x'cr' FET16 current in amps FET17_x.x'cr' FET17 current in amps FET18_x.x'cr' FET18 current in amps FET19_x.x'cr''lf'] FET19 current in amps 5.8.3.4 Utility Status Utility Status: Confirmation: >DEV/RUS_'cr' COMM_aaaaaa'cr' RS-232 or RS-485 ADD_xxx'cr' Address (001 to 255) BR_nnnn'cr' Baud Rate (300 to 9600) PAR_nn'cr' Parity (OD or EV) CON_xx'cr' LCD Contrast (0 to 30) LCD_xx'cr''lf'] LCD Brightness (0 to 30)