Prime power input, Physical dimensions, Environmental specifications – Comtech EF Data XPA-200 User Manual
Page 20: Front panel controls
XPA200-7984-I-OPT1, X-Band SSPA
Introduction
XPA200-7984-I-OPT1, REV.3
1-4
1.4 Prime Power Input
The power input requirements for the XPA200-7984-I X-Band SSPA
are as follows:
!
115 volts AC.
!
47 to 63 Hz.
!
2600 VA (approx. 1800W) nominal
1.5 Physical Dimensions
!
Width:
19 inches.
!
Height:
12.25 inches.
!
Depth:
24 inches.
!
Weight:
100 lbs.
1.6 Environmental Specifications
!
Temperature:
0 to +50 degrees C operating.
(Note: P1dB guaranteed only 0 to 40C.
Operation above 40C not recommended).
!
Humidity:
10 to 95% noncondensing operation.
1.7 Front Panel Controls
The front panel contains a User Interface Key-Pad which is used
by a local operator to input commands to the SSPA. The key-pad
is used to select the configuration for operating and monitoring
the status of the SSPA. In conjunction with the front panel two
line, twenty four character, LCD display, the key-pad allows the
operator to select one of five configurations. The configuration
functions are "Configuration Menu", "Monitor Status Menu",
"Currents Faults Menu", "Stored Faults Menu" and "Utility
Functions Menu".