Comtech EF Data XPA-200 User Manual
Page 66

XPA200-7984-I-OPT1, X-Band SSPA
Remote Control
Remote Control
XPA200-7984-I-OPT1, Rev.2
5-14
5.8.3.5 Alarm Status
Alarm Status:
Confirmation: >DEV/RAS_'cr' +28_xx'cr' +28 VDC Fault +12_xx'cr' +12 VDC Fault -12_xx'cr' -12 VDC Fault +5_xx'cr' +5 VDC Fault -5_xx'cr' -5 VDC Fault +10_1_xx'cr' +10 PS#1 Fault +10_2_xx'cr' +10 PS#2 Fault TEMP_xx'cr' Temperature Fault FAN1_xx’cr’ Fan 1 Fault FAN2_xx’cr’’lf’] Fan 2 Fault xx = OK or FT 5.8.3.6 Summary Alarm Status Summary alarm is set to Fault (FT) if any of the items in paragraph 5.8.4.5 are faulted. Summary Alarm: xx = OK or FT Confirmation: >DEV/SAS_xx'cr''lf'] 5.8.3.7 Terminal Status Change The TSC_ command can be used to determine if the status of the terminal has changed since it was last polled. If any of the parameters listed in the RCS or RUS commands have changed as a result of user operations or if any new fault condition occur the TSC_ command will return YES. The TSC_ command will then continue to return YES until any of the following commands are received: RCS_, RUS_, RAS_, PACRCS_, PACRUS_, or PACRAS. Configuration Status: Confirmation: >DEV/TSC_nnn'cr''lf'] nnn = YES/NO