XPA200-7984-I-OPT1, X-Band SSPA

Introduction

XPA200-7984-I-OPT1, REV.3

1-9

1.11.2 Customer Discrete Control, Connector J4

The Customer Discrete Control connector, J4, is a 19 pin

circular connector, type MS3112E14-19S. The pin-out

specifications is contained in Table 1-2. The mating connector

is a MS3116F14-19P.

Table 1-2.

J4, Customer Discrete Control Connector Pin-Out

Pin

Signal Name

Description

A

External Mute

Cmd

External Mute Command. TTL input “high”

mutes the unit.

B

External Mute

Common

External Mute Common.

G

Local Online

Common

Local Online Status Common.

H

Local Online

NO

Tied to pin G when Online, else open.

N

Summary Fault

Common

Summary Fault Status Common.

P

Summary fault

NO

Open when Faulted, else tied to Pin N.

Note: All other pins are unused.