XPA200-7984-I-OPT1, X-Band SSPA

Installation

XPA200-7984-I-OPT1, Rev.2

2-1

Section 2

Installation/Operation with

Mitec

2723B

Variable Phase Combiner and

Redundant Switching System

2.1 Unpacking and Inspection

This section is intended to give a brief explanation on how to

setup and operate two Comtech XPA200 SSPAs with the Mitec 2723B

Variable Phase Combiner and Redundant Switching System. More detailed

explanations on operation of the SSPA are contained in later sections

of this manual. More detailed operating instructions for the Mitec

Combiner and redundant switching system can be found in it’s

associated manual.

Inspect the shipping container for damage. The shipping

container and packing materials should be retained for possible re-

shipment. Check to determine that all parts, materials and

documentation have been shipped with the SSPA. The SSPA should be

inspected for possible damage, and then tested for proper operation.

If the shipment is incomplete, or there is mechanical damage, or

the SSPA does not operate properly, notify the COMTECH Customer

Service representative immediately. If there is damage to the

shipping container, notify the carrier, and retain all shipping

materials for inspection by the carrier.

2.2 Rack Mount Installation

2.2.1 XPA200 Installation

The XPA200-7984-I X-Band SSPA is designed for installation to

mount in a standard 19 inch rack cabinet or enclosure. The SSPA

chassis requires 12.25 (7RU) inches of panel height space.

Adequate air ventilation should be provided to the rack

mounted equipment. Cool air is taken in through the front panel and