Page 29: Installation/operation with mitec
XPA200-7984-I-OPT1, X-Band SSPA
Installation
XPA200-7984-I-OPT1, Rev.2
2-1
Section 2
Installation/Operation with
Mitec
2723B
Variable Phase Combiner and
Redundant Switching System
2.1 Unpacking and Inspection
This section is intended to give a brief explanation on how to
setup and operate two Comtech XPA200 SSPAs with the Mitec 2723B
Variable Phase Combiner and Redundant Switching System. More detailed
explanations on operation of the SSPA are contained in later sections
of this manual. More detailed operating instructions for the Mitec
Combiner and redundant switching system can be found in it’s
associated manual.
Inspect the shipping container for damage. The shipping
container and packing materials should be retained for possible re-
shipment. Check to determine that all parts, materials and
documentation have been shipped with the SSPA. The SSPA should be
inspected for possible damage, and then tested for proper operation.
If the shipment is incomplete, or there is mechanical damage, or
the SSPA does not operate properly, notify the COMTECH Customer
Service representative immediately. If there is damage to the
shipping container, notify the carrier, and retain all shipping
materials for inspection by the carrier.
2.2 Rack Mount Installation
2.2.1 XPA200 Installation
The XPA200-7984-I X-Band SSPA is designed for installation to
mount in a standard 19 inch rack cabinet or enclosure. The SSPA
chassis requires 12.25 (7RU) inches of panel height space.
Adequate air ventilation should be provided to the rack
mounted equipment. Cool air is taken in through the front panel and