turboIP-G2 Performance Enhancement Proxy

Revision 2

Rear Panel Connectors

CD-TURBOIP-G2

3–3

3.4

10/100/1000 BaseT Ethernet MGT Port (1X RJ-45)

Available on units manufactured from November 2010 forward, this port is a standard RJ-45
receptacle used for turboIP-G2 monitor and control (M&C) via Telnet, HTTP, and SNMP. It
can also used for updating turboIP-G2 firmware. This receptacle uses a UTP cable to connect
to an Ethernet hub, router, switch, PC, etc.

The connector pinouts are as follows:

Pin #

Description

Direction

1

TX+ Out

2

TX- Out

3

Rx+ In

4

N/A

5

N/A

6

Rx- In

For detailed information on M&C operations, see Chapter 5. MANAGEMENT

VIA THE

CLI

OR

WEB SERVER GUI.

3.5

IEC Line Input (AC Power) Connector

A standard, detachable, non-locking, 3-prong power cord (IEC plug) supplies the
Alternating Current (AC) power to the turboIP-G2. Note from Figure 3-1 that the
orientation and location of the connector differs between the turboIP-G2 1/2-Width
and Full-Width units.

Note the following:

AC Power Specifications

Input Power

1/2-Width Unit: 100 to 240 VAC, 50 to 60 Hz, 90 W max
Full-Width Unit: 90 to 264 VAC, 47 to 63 Hz, 110 W max.

Input Voltage

100 to 240 VAC, +6/-10% - autosensing
(total absolute max. range is 90 to 254 VAC)

Connector Type

IEC