4 10/100/1000 baset ethernet mgt port (1x rj-45), 5 iec line input (ac power) connector – Comtech EF Data turboIP-G2 User Manual
Page 47
turboIP-G2 Performance Enhancement Proxy
Revision 2
Rear Panel Connectors
CD-TURBOIP-G2
3–3
3.4
10/100/1000 BaseT Ethernet MGT Port (1X RJ-45)
Available on units manufactured from November 2010 forward, this port is a standard RJ-45
receptacle used for turboIP-G2 monitor and control (M&C) via Telnet, HTTP, and SNMP. It
can also used for updating turboIP-G2 firmware. This receptacle uses a UTP cable to connect
to an Ethernet hub, router, switch, PC, etc.
The connector pinouts are as follows:
Pin #
Description
Direction
1
TX+ Out
2
TX- Out
3
Rx+ In
4
N/A
5
N/A
6
Rx- In
For detailed information on M&C operations, see Chapter 5. MANAGEMENT
VIA THE
CLI
OR
WEB SERVER GUI.
3.5
IEC Line Input (AC Power) Connector
A standard, detachable, non-locking, 3-prong power cord (IEC plug) supplies the
Alternating Current (AC) power to the turboIP-G2. Note from Figure 3-1 that the
orientation and location of the connector differs between the turboIP-G2 1/2-Width
and Full-Width units.
Note the following:
AC Power Specifications
Input Power
1/2-Width Unit: 100 to 240 VAC, 50 to 60 Hz, 90 W max
Full-Width Unit: 90 to 264 VAC, 47 to 63 Hz, 110 W max.
Input Voltage
100 to 240 VAC, +6/-10% - autosensing
(total absolute max. range is 90 to 254 VAC)
Connector Type
IEC