SDM-9600 with SDM-9606 Blades Hardware Installation Guide

5-16

Memotec Inc.

5.9.2

E1/T1 Port Status LEDs

Three LEDs are located to the left of each digital interface on the front face of the SDM-
9606 blade:

SYN-AL

(top),

T1-E1

(middle) and

D-CH

(bottom).

Table 5-9

explains how

these LEDs should be interpreted.

5.9.3

Supporting E1-75 on an E1/T1 Port

An E1-75 connection requires an adaptor for E1-75 operations, as described in the next

section). You must provide strain relief for the cables to ensure that they do not loosen
from the digital port. See

“Hardware Strapping for E1 Ports” on page 4-8

.

LED

Color

Indication

SYN-AL

Off

Either the port is not configured (State = DISABLED) or
it did not pass the power-up self test and is not func-
tional

Green

The digital link is synchronized

Amber

One or more Yellow Alarms have occurred on the link.

Note:

The NetPerformer assumes that the physical
link is out of sync when a yellow alarm is
detected, and brings down any active channels
on that link

Red

A fatal error has occurred, for example, loss of synchro-

nization on the digital link

T1-E1

Off

Either the port is not configured or it did not pass the
power-up self test and is not functional

Amber

The port has been configured for T1 operation

Green

The port has been configured for E1 operation

D-CH

Off

The D-channel is DOWN

Green

The D-channel is UP

Table 5-9: Status LED indicators on SDM-9606 digital interfaces