Esc : 000, Esc m n 0 – Compuprint MDP40B Programmer Manual User Manual
Page 185

C-43
ESC : 000
Copy character generator into user memory. (Olivetti PR2, PR40+)
ASCII Code
ESC : 0 0 0
Hexadecimal Value
1B 3A 30 30 30
Decimal Value
27 58 48 48 48
The command transfers the current character generator set into the user memory.
The command is not accepted (command specification error) if:
• It is sent inside a printing field.
• It is sent with the OCR-A or B Font selected, in that these fonts cannot be loaded
into the user memory.
ESC m n 0
Select character generator. (Olivetti PR2, PR40+)
ASCII Code
ESC m n 0
Hexadecimal Value
1B 6D n 30
Decimal Value
27 109 n 48
The command selects the current character generator or the one in the user memory
depending on the decimal value of parameter n.
n Generator
selected
0
Current character generator
1
Character generator in user memory
The command is not accepted if it is sent with the OCR-A or B Font selected.