C-22
BS
Back space. (Olivetti PR2)
ASCII Code
BS
Hexadecimal Value
08
Decimal Value
8
This command repositions a character backward with current print pitch. If the
command is sent in zero column, it is ignored.
The command generates command specification errors if the command is sent with no
characters to print.
ESC 7
Line feed back. (Olivetti PR2, PR40+, 2845)
ASCII Code
ESC 7
Hexadecimal Value
1B 37
Decimal Value
27 55
Prints the current line and executes a back line feed according to the selected vertical
spacing.
If the LF+CR feature has been selected in the printer Set-Up, the printing position is
set at the left margin.
The command is not accepted if:
• The print line is the first on the form (the line is printed).
• Sent without a document inserted.