beautypg.com

Analogue inputs (ain 1-8), Ps-8810, Control port analogue inputs – BSS Audio Prosys PS-8810 Owner's Manual User Manual

Page 109

background image

- 109 -

PS-8810

DIGITAL SIGNAL PROCESSOR

The Control Port analogue inputs allow a 0 to +10VDC signal to
be input to allow remote control of continuously variable objects
such as faders or filter frequencies. They can also be used to
control switched objects (just like the Digital Inputs). When the Edit
button associated with a particular input is pressed, the Control
Port Assignment Dialogue box appears and allows programming of
the input just as was discussed for the Digital Inputs.

These inputs can be used to sense the presence of an analogue
input signal level, such as ordinary 10kOhm linear potentiometers
for level control. Analogue inputs can alternately be set to sense
simple contact closure.

Sample Control Port Digital Input Circuit

A screw-terminal board with barrier-block to DB37M connections
makes it easy to interface external circuitry to the Control Port.

ComputerBoards, Inc. offers a suitable screw-terminal board (part
number CIO-MINI37), along with an enclosure (part number ENC-
MINI37) for this use.
Contact ComputerBoards, Inc. at www.computerboards.com or
(508)946-5100.

Control Port

Analogue Inputs

Analogue Inputs

(AIN 1-8)