Digital outputs, Ps-8810, Control port digital outputs – BSS Audio Prosys PS-8810 Owner's Manual User Manual
Page 107

- 107 -
PS-8810
DIGITAL SIGNAL PROCESSOR
Control Port
Digital Outputs
Digital Outputs
There are eight digital outputs. Each output may be controlled
manually, configured to indicate the state of a binary object or,
configured to indicate whether a particular Preset is loaded. There
is one indicator and five controls for each output:
•
Pin State Indicator: indicates the logical ‘Pin-High’ or ‘Pin-
Low’ status of the actual hardware output
•
Manual: directly controls the output state of the
corresponding pin when in Manual mode
•
Polarity: changes the polarity of the digital output regardless
of the pin control mode
•
Reflect Manual: causes the output to directly reflect the state
of its Manual control
•
Reflect Object: causes the output to reflect the state of the
selected binary object within the BSS PS-8810. Only a single
object may be specified.
•
Reflect Preset: causes the output to reflect whether the
chosen Preset number is loaded within the BSS PS-8810
When the Control Port digital outputs are turned 'on', +10VDC at
10 mA is supplied across the output to ground. A total of 1 amp of
current is available.