5. Hold a white label against the sensor as shown.

a. When you cover the sensor with a label, you will see:

DEMAND = ###
BLOCKED

Valid values are 480-999.

b. When you remove the label from the sensor, you will

see:

DEMAND = ##
CLEAR

Valid values are 0-288.

6. Close the label deflector, and then press

b

.

To run the Black Mark test:

1. From the HDW TEST MENU, press

>

until you see:

Serial Port
Sensors

2. Press

e

. You will see:

SENSORS TEST
On-Demand

3. Press

>

until you see:

SENSORS TEST
Black Mark

4. Press

e

.

5. Open the supply cover.

6030 Operator’s Handbook

10-12