beautypg.com

4 dam and cc mode calibrations, 1 dam, range i offset and gain, items 9 and 10, Cc m – AMETEK SL Series Calibration Manual User Manual

Page 15: Alibrations, Dam, range i offset and gain, items 9 and 10 -7, Dam, r

background image

Elgar Electronics Corporation

Calibration

2.4

DAM AND CC MODE CALIBRATIONS

The following three steps apply to both DAM and CC Mode Calibration, Items
9-20:

1.

Connect the DC Power supply to input terminal, as shown in Figure
2-3
.

2.

Set the power supply voltage to +5Vdc.

Figure 2-3. Connections for DAM and CC Mode Calibrations

2.4.1

DAM, R

ANGE

I O

FFSET AND

G

AIN

, I

TEMS

9

AND

10

1.

Press the

© key to go to Item 9.

2.

LOAD OFF.

3.

PRES ON.

4.

Set the load current as shown in Table 2-9 for the model being
calibrated.

5.

PRES OFF.

6.

LOAD ON.

7.

Adjust using the

…† keys until the load DAM reading matches the

DMM reading.

MODEL

Current Setting

MODEL

Current Setting

SLM-60-30-150 0.00A

SLH-60-120-600 0.00A

SLM-60-60-300 0.00A

SLH-60-120-1200 0.00A

SLM-250-10-300 0.00A

SLH-60-120-1800 0.00A

SLM-500-10-300 0.00A

SLH-60-240-1200 0.00A

SLM-60-15-75 0.00A

SLH-60-240-1800 0.00A

SLH-60-360-1800

0.00A

SLH-500-60-1800

0.00A

Table 2-9. DAM, Range I Offset Adjustment Settings (Item 9)

SLM/SLH Calibration Manual

2-7