4 dam and cc mode calibrations, 1 dam, range i offset and gain, items 9 and 10, Cc m – AMETEK SL Series Calibration Manual User Manual
Page 15: Alibrations, Dam, range i offset and gain, items 9 and 10 -7, Dam, r

Elgar Electronics Corporation
Calibration
2.4
DAM AND CC MODE CALIBRATIONS
The following three steps apply to both DAM and CC Mode Calibration, Items
9-20:
1.
Connect the DC Power supply to input terminal, as shown in Figure
2-3.
2.
Set the power supply voltage to +5Vdc.
Figure 2-3. Connections for DAM and CC Mode Calibrations
2.4.1
DAM, R
ANGE
I O
FFSET AND
G
AIN
, I
TEMS
9
AND
10
1.
Press the
© key to go to Item 9.
2.
LOAD OFF.
3.
PRES ON.
4.
Set the load current as shown in Table 2-9 for the model being
calibrated.
5.
PRES OFF.
6.
LOAD ON.
7.
Adjust using the
keys until the load DAM reading matches the
DMM reading.
MODEL
Current Setting
MODEL
Current Setting
SLM-60-30-150 0.00A
SLH-60-120-600 0.00A
SLM-60-60-300 0.00A
SLH-60-120-1200 0.00A
SLM-250-10-300 0.00A
SLH-60-120-1800 0.00A
SLM-500-10-300 0.00A
SLH-60-240-1200 0.00A
SLM-60-15-75 0.00A
SLH-60-240-1800 0.00A
SLH-60-360-1800
0.00A
SLH-500-60-1800
0.00A
Table 2-9. DAM, Range I Offset Adjustment Settings (Item 9)
SLM/SLH Calibration Manual
2-7