beautypg.com

1 dvm, range i offset and gain, items 1 and 2, Dvm, range i offset and gain, items 1 and 2 -2, Dvm, r – AMETEK SL Series Calibration Manual User Manual

Page 10

background image

Calibration

Elgar Electronics Corporation

2.2.1

DVM, R

ANGE

I O

FFSET AND

G

AIN

, I

TEMS

1

AND

2

7.

Set the DC Voltage Standard to the Input Voltage value shown in
Table 2-1 for the load model being calibrated.

8.

Use the

…† keys to adjust the load DVM display until it matches the

DMM reading.

MODEL

MODEL

Input Voltage

Input Voltage

SLM-60-30-150 0.200V

SLH-60-120-600 0.200V

SLM-60-60-300 0.200V

SLH-60-120-1200 0.200V

SLM-250-10-300 0.200V SLH-60-120-1800 0.200V
SLM-500-10-300 0.400V SLH-60-240-1200 0.200V
SLM-60-15-75 0.200V

SLH-60-240-1800 0.200V

SLH-60-360-1800 0.200V

SLH-500-60-1800 0.400V

Table 2-1. DVM, Range I Offset Adjustment Settings (Item 1)

9.

Press the

© key to go to Item 2.

10.

Set the DC Voltage Standard to the Input Voltage value shown in
Table 2-2 for the load model being calibrated.

11.

Use the

…† keys to adjust the load DVM display until it matches the

DMM reading.

12.

Repeat steps 1 through 5 (press

ª to return to Item 1) until no further

adjustments are necessary for the load DVM to match the DMM
reading.

MODEL

MODEL

Input Voltage

Input Voltage

SLM-60-30-150 15.00V

SLH-60-120-600 15.00V

SLM-60-60-300 15.00V

SLH-60-120-1200 15.00V

SLM-250-10-300 30.00V

SLH-60-120-1800 15.00V

SLM-500-10-300 60.00V

SLH-60-240-1200 15.00V

SLM-60-15-75 15.00V

SLH-60-240-1800 15.00V

SLH-60-360-1800 15.00V

SLH-500-60-1800 60.00V

Table 2-2. DVM Range I Gain Adjustment Settings (Item 2)

2-2

SLM/SLH Calibration Manual