Elgar Electronics Corporation

Calibration

2.2.2

DVM, R

ANGE

II O

FFSET AND

G

AIN

, I

TEMS

3

AND

4

1.

Press the

© key to go to Item 3.

2.

Set the DC Voltage Standard to the Input Voltage value shown in
Table 2-3 for the model being calibrated.

3.

Use the

…† keys to adjust the load DVM display until it matches the

DMM reading.

Item 3

Item

3

Input Voltage

Input Voltage

SLM-60-30-150 0.200V SLH-60-120-600 0.200V
SLM-60-60-300 0.200V SLH-60-120-1200 0.200V
SLM-250-10-300 0.200V SLH-60-120-1800 0.200V
SLM-500-10-300 0.400V SLH-60-240-1200 0.200V
SLM-60-15-75 0.200V SLH-60-240-1800 0.200V

SLH-60-360-1800 0.200V

SLH-500-60-1800 0.400V

Table 2-3. DVM, Range II Gain Adjustment Settings (Item 3)

4.

Press the

© key to go to Item 4.

5.

Set the DC Voltage Standard to the Input Voltage value shown in
Table 2-4 for the model being calibrated.

6.

Use the

…† keys to adjust the load DVM display until it matches the

DMM reading.

7.

Repeat steps 1 through 6 (press

ª to return to Item 3) until no further

adjustments are necessary for the load DVM to match the DMM
reading.

MODEL

Input Voltage

MODEL

Input Voltage

SLM-60-30-150 60.00V

SLH-60-120-600 60.00V

SLM-60-60-300 60.00V

SLH-60-120-1200 60.00V

SLM-250-10-300 250.00V

SLH-60-120-1800 60.00V

SLM-500-10-300 500.00V

SLH-60-240-1200 60.00V

SLM-60-15-75 60.00V

SLH-60-240-1800

60.00V

SLH-60-360-1800

60.00V

SLH-500-60-1800

500.00V

Table 2-4. DVM, Range II Gain Adjustment Settings (Item 4)

SLM/SLH Calibration Manual

2-3