Advanced parameter settings, Hidden parameters, Required user clock frequency – Altera 50G Interlaken MegaCore Function User Manual
Page 79: Advanced parameter settings -1, Hidden parameters -1, Required user clock frequency -1

Advanced Parameter Settings
9
2015.05.04
UG-01140
Advanced users can further customize the 50G Interlaken IP core by modifying hidden parameters that
are not displayed in the 50G Interlaken parameter editor. These parameters can only be modified in the
Verilog RTL instantiation in the generated
ilk_core_50g.sv
file and the instantiation of the 50G Interlaken
IP core in the top level design file.
The following topics describe the hidden parameters and tell you how to modify their values.
on page 9-1
Modifying Hidden Parameter Values
on page 9-4
Hidden Parameters
The advanced parameters affect the behavior of the 50G Interlaken MegaCore function.
Note: Altera recommends that you do not modify any RTL parameters that are not listed here. Some
undocumented modifications might overwrite settings you specify in the parameter editor.
To customize your 50G Interlaken MegaCore function, you can modify parameters to specify the
following properties:
on page 9-2
SWAP_TX_LANES and SWAP_RX_LANES (Data Word Lane Swapping)
on page 9-2
on page 9-4
Required User Clock Frequency
The
TX_USR_CLK_MHZ
parameter specifies the expected frequency of the input clocks
tx_usr_clk
and
rx_usr_clk
.
The default value of this parameter is 250 MHz. The range of allowed values is 200 MHz to 300 MHz. You
must drive the two input clocks at the frequency specified by this parameter.
©
2015 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are
trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as
trademarks or service marks are the property of their respective holders as described at
www.altera.com/common/legal.html
. Altera warrants performance
of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any
products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information,
product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device
specifications before relying on any published information and before placing orders for products or services.
www.altera.com
101 Innovation Drive, San Jose, CA 95134