Altera 50G Interlaken MegaCore Function User Manual
Page 59

If you do not use the management interface, drive the management inputs as follows:
•
mm_clk
must connect to a stable clock. However, the clock signal need not be of unusually high quality.
•
mm_clk_locked
must be tied to zero.
•
mm_read
and
mm_write
must be tied to zero.
If you use the management interface, drive the control lines as shown in the examples and observing the
following constraints:
• During a write operation, you must maintain the the
mm_write
signal asserted for at least two clock
cycles. Back-to-back writes must be separated by at least one clock cycle.
• During a read operation, you must maintain the
mm_read
signal asserted for at least two clock cycles.
Back-to-back reads must be separated by at least one clock cycle.
Figure 5-1: 50G Interlaken IP Core Management Interface Write Operation
Shows the timing requirements for a write operation on the 50G Interlaken IP core management
interface.
mm_clk
mm_write
mm_addr[15:0]
mm_wdata[31:0]
Don’t Care
0x0012
0x0013
Don’t Care
Don’t Care
wdata0
wdata1
Don’t Care
Figure 5-2: 50G Interlaken IP Core Management Interface Read Operation
Shows the timing requirements for a read operation on the 50G Interlaken IP core management interface.
The IP core asserts the
mm_rdata_valid
signal one cycle after the
mm_read
signal is asserted.
mm_clk
mm_read
mm_addr[15:0]
mm_rdata_valid
mm_rdata[31:0]
Don’t Care
0x0000
0x0001
Don’t Care
Previous Value
rdata0
rdata1
Related Information
UG-01140
2015.05.04
50G Interlaken IP Core Management Interface
5-13
50G Interlaken MegaCore Function Signals