beautypg.com

Switching – Pilz PSSnet SHL 8T MRP User Manual

Page 65

background image

Switching

PSSnet SHL - Web- based Interface

Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern

4.4 Multicasts

65

The parameters
– Max. Response Time,
– Send Interval and
– Group Membership Interval
have a relationship to each other:

Max. Response Time < Send Interval < Group Membership Interval.

If you enter values that contradict this relationship, the device then replaces
these values with a default value or with the last valid values.

Parameter

Meaning

Value range

Default setting

IGMP Querier
IGMP Querier en-
abled

Switch query function on/off

on/off

off

Protocol Version

Select IGMP version 1, 2 or 3.

1, 2, 3

2

Send Interval

Enter the interval at which the switch
sends query packets.
All IGMP-capable terminal devices re-
spond to a query with a report mes-
sage, thus generating a network load.

2-3599 s

a

125 s

IGMP settings
Current querier IP
address

Display the IP address of the router/
switch that contains the query function.

Max. Response
Time

Enter the time within which the Multi-
cast group members respond to a
query.
The Multicast group members select a
random value within the response time
for their response, to prevent all the
Multicast group members responding
to the query at the same time.

Protocol Version
- 1,2: 1-25 s

a

- 3: 1-3598 s

a

10 s

Group Membership
Interval

Enter the period for which a dynamic
Multicast group remains entered in the
device if it does not receive any report
messages.

3-3600 s

a

260 s

Table 13: IGMP Querier and IGMP settings

a.) Note the connection between the parameters Max. Response Time,
Send Interval and Group Membership Interval,

(see table

30)