Redundancy

114

6.3 Rapid Spanning Tree

PSSnet SHL - Web- based Interface

Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern

Figure 38: RSTP Port dialog

Oper Point-
ToPoint

If this port has a full-duplex link to
another RSTP device, the value for
Oper PointToPoint will become
„true“, else it will become „false“
(e.

g., if a hub is connected). A

Point-to-point connection is a direct
connection between two RSTP de-
vices. The direct, local communica-
tions between the two switches
results in a short reconfiguration
time.

true, false

auto
(is calculated):
FDX = true
HDX = false

Designated
Root

Displays the bridge identification of
the designated root Switch for this
port.

Bridge identification
(hexadecimal)

-

Designated
Costs

Display of the costs of the path from
this port to the root Switch.

Costs

-

Designated Port Display of the port identifier of the

port that creates the connection to
the root Switch for this port (on the
designated Switch).

Port identification
(hexadecimal) and
port number

-

Parameter

Meaning

Value range

Default setting

Table 42: Port-related RSTP settings and displays