Redundancy, 3 rapid spanning tree 113 – Pilz PSSnet SHL 8T MRP User Manual
Page 113
Redundancy
PSSnet SHL - Web- based Interface
Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern
6.3 Rapid Spanning Tree
113
Parameter
Meaning
Value range
Default setting
STP State En-
able
Here you can turn RSTP on or off
for this port. If you turn RSTP off for
this port while RSTP is globally en-
abled for the device, the device will
discard RSTP frames received on
this port.
on,
off
on
Port State
Displays the port state
disabled,
forwarding,
discarding,
blocking,
learning
-
Priority
Here you enter the first byte of the
port identification.
16
<
n*16
<
240
128
Port Path Cost
Enter the path costs to indicate pref-
erence for redundant paths. If the
value is “0”, the Switch automatical-
ly calculates the path costs depend-
ing on the transmission rate.
0 - 200.000.000
0
Admin Edge
Port
If the parameter is set to „true“, the
port will transition to the forwarding
state. If the port nevertheless re-
ceives a RSTP frame, it will transi-
tion to the blocking state and the
bridge will then determine the new
port role.
.If the parameter’s value is „false“,
the port remains in the blocked state
until the bridge has determined the
port role. Only after that will the port
transition to its final state.
true, false
false
Oper Edge Port Is „true“ if no RSTP frames were
received, i. e.,
a
terminal
device
that
sends no RSTP frames is connect-
ed to this port. Is „false“ if RSTP
frames were received, i.
e.,
no
terminal device but a bridge is
connected.
true, false
-
Auto Edge Port The setting for Auto Edge Port only
takes effect if the parameter Oper
Edge Port has been set to „false“.
if Auto Edge Port is set to „true“, the
port will transition to the forwarding
state within 1.5
* Hello Time
(3
seconds). If is is set to „false“, it
will take 30
seconds until the edge
port forwards data frames.
true, false
false
Table 42: Port-related RSTP settings and displays